EasyManua.ls Logo

Juniper ACX2000 Configuration Guide

Juniper ACX2000
3270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
For example:
[edit interfaces coc3-1/0/0]
user@host# up
4. Configure the channelized OC1 interface and the sublevel interface partition index,
and set the interface type as ct1.
[edit interfaces]
user@host# set coc1-1/0/0:1 partition partition-number interface-type ct1
For example:
[edit interfaces]
user@host# set coc1-1/0/0:1 partition 1 interface-type ct1
To verify the configuration, use the show command at the [edit interfaces] hierarchy
level.
[edit interfaces]
user@host# show
coc3-1/0/0 {
partition 1 oc-slice 1 interface-type coc1;
}
coc1-1/0/0:1 {
partition 1 interface-type ct1;
}
Configuring CT1 Channels Down to DS Interfaces
To configure CT1 channels down to a DS interface, include the partition statement at the
[edit interfaces ct1-mpc-slot/mic-slot/port-number:channel:channel] hierarchy level:
1. In configuration mode, go to the [edit interfaces
ct1-mpc-slot/mic-slot/port-number:channel:channel] hierarchy level.
[edit]
user@host# edit interfaces ct1-mpc-slot/mic-slot/port-number:channel:channel
For example:
[edit]
user@host# edit interfaces ct1-1/0/0:1:1
2. Configure the partition, the time slots, and the interface type.
[edit interfaces ct1-mpc-slot/mic-slot/port-number:channel:channel]
user@host# set partition partition-number timeslots timeslots interface-type ds
For example:
[edit interfaces ct1-1/0/0:1:1]
user@host# set partition 1 timeslots 1-4 interface-type ds
209Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Configuring CESoPSN Support on Interfaces

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Juniper ACX2000 Specifications

General IconGeneral
ModelACX2000
Product SeriesACX Series
CategoryNetwork Router
Maximum Throughput60 Gbps
Throughput60 Gbps
Operating SystemJunos OS
Memory4 GB
Storage8 GB
Power SupplyAC or DC
Routing ProtocolsBGP, OSPF, IS-IS, RIP
Operating Temperature-40° to 149°F (-40° to 65°C)
Humidity5% to 95% non-condensing