t1-options (BITS Interfaces Signal Type)
Syntax t1-options {
framing (esf | sf);
}
Hierarchy Level [edit chassis synchronization interfaces bits signal-type]
Release Information Statement introduced in Junos OS Release 12.3 for ACX Series Routers.
Description Specify options for the T1 signal type for the building-integrated timing supply (BITS)
interface. Valid only if t1 is the signal-type configured at the [edit chassis synchronization
source interfaces interface-name bits signal-type].
Options The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
External Clock Synchronization Overview for ACX Series Routers on page 226
Configuring External Clock Synchronization for ACX Series Routers on page 228
Synchronous Ethernet Overview
show chassis synchronization on page 2386
temperature (Alarm Relay Output)
Syntax temperature;
Hierarchy Level [edit chassis alarm relay output port port-number ]
Release Information Statement introduced in Junos OS Release 12.3.
Description Configure the output relay alarm port to respond when the system temperature goes to
the red alarm status.
Required Privilege
Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related
Documentation
User-Defined Alarm Relay Overview on page 158
show chassis craft-interface on page 1865
show chassis alarms on page 1845