test services rpm rfc2544-benchmarking test
List of Syntax Syntax (ACX Series) on page 3211
Syntax (MX104 Router) on page 3211
Syntax (ACX Series) test services rpm rfc2544-benchmarking test
<clear-counters>
<routing-instance routing-instance-name>
<test-name>
<test-id>
<start>
<stop>
Syntax (MX104
Router)
test services rpm rfc2544-benchmarking test
<test-name>
<test-id>
<start>>
<stop>
Release Information Command introduced in Junos OS Release 12.3X52 for ACX Series routers.
Command introduced in Junos OS Release 13.3R1 for MX104 3D Universal Edge routers.
Description Start or stop an RFC 2544-based benchmarking test. You can start or stop all of the test
names that are defined on a router, or start or stop a specific test name. You can also
stop a test based on its test identifier. You can also clear the statistical counters
associated with the test. When you trigger an RFC 2544-based benchmarking test, it
passes through a series of states. These states are displayed in the Test state field in the
brief or displayed output information of the show services rpm rfc2544-benchmarking
command.
NOTE: The RFC 2544 test is stopped at the initiator automatically after the
test successfully completes all of the test steps. You need not explicitly enter
the test services rpm rfc2544-benchmarking test <test-name | test-id> stop
command. However, at the reflector, you must explicitly enter this command
to stop the test after the test is completed at the initiator.
When a Layer 2 circuit pseudowire is not up, you cannot start the RFC 2544-based
benchmarking test in reflection test mode by entering the test services rpm
rfc2544-benchmarking test test-name start command. If you attempt to start the reflection
test mode, a message is displayed explaining the reason for the failure to commence the
test.
Options start—Start the RFC 2544-based benchmarking test
stop—Terminate the RFC 2544-based benchmarking test
3211Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands