manual (Master Clock)
Syntax manual;
Hierarchy Level [edit protocols ptp master interface interface-name unicast-mode clock-client ip-address
local-ip-address local-ip-address]
Release Information Statement introduced in Junos OS Release 12.3 for ACX Series Routers.
Description Configure this remote clock client when it does not use unicast negotiation to join the
boundary master. When this statement is configured, the boundary master starts sending
announce and synchronization messages to the remote client.
NOTE: The number of manual clients you can configure varies depending on
the number of secure clients configured. You can configure any combination
of manual and secure clients as long as the combined total amounts to 256.
Required Privilege
Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Related
Documentation
• IEEE 1588v2 PTP Boundary Clock Overview on page 234
• Configuring Precision Time Protocol Clocking on page 243
• Configuring a PTP Master Boundary Clock on page 244
• Example: Configuring a PTP Boundary Clock With Unicast Negotiation on page 250
• Example: Configuring a PTP Boundary Clock on page 248
1595Copyright © 2017, Juniper Networks, Inc.
Chapter 41: Configuration Statements