clock-source (PTP Unicast Slave Interface)
Syntax clock-source ip-address {
local-ip-address local-ip-address;
asymmetry number;
}
}
Hierarchy Level [edit protocols ptp slave interface interface-name unicast-mode]
Release Information Statement introduced in Junos OS Release 12.2.
Statement introduced in Junos OS Release 17.3 for the QFX Series.
Description Configure the parameters of the Precision Time Protocol (PTP) master—clock source—to
which this slave synchronizes. You can configure up to four clock sources for one interface,
or one clock source for each of four different interfaces.
Options ip-address—IP address of the PTP master.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
routing—To view this statement in the configuration.
routing-controlTo add this statement to the configuration.
Related
Documentation
IEEE 1588v2 Precision Timing Protocol (PTP) on ACX Series Universal Access Routers