clock-source (PTP Unicast Slave Interface)
Syntax clock-source ip-address {
local-ip-address local-ip-address;
asymmetry number;
}
}
Hierarchy Level [edit protocols ptp slave interface interface-name unicast-mode]
Release Information Statement introduced in Junos OS Release 12.2.
Statement introduced in Junos OS Release 17.3 for the QFX Series.
Description Configure the parameters of the Precision Time Protocol (PTP) master—clock source—to
which this slave synchronizes. You can configure up to four clock sources for one interface,
or one clock source for each of four different interfaces.
Options ip-address—IP address of the PTP master.
The remaining statements are explained separately. See CLI Explorer.
Required Privilege
Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Related
Documentation
• IEEE 1588v2 Precision Timing Protocol (PTP) on ACX Series Universal Access Routers
on page 237
• Precision Time Protocol Overview
1467Copyright © 2017, Juniper Networks, Inc.
Chapter 41: Configuration Statements

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals