max-unknown-messages
Syntax max-unknown-messages messages-per-minute;
Hierarchy Level [edit protocols pcep pce pce-id]
Release Information Statement introduced in Junos OS Release 12.3.
Support for PTX Series added in Junos OS Release 14.2.
Support for QFX10000 switches added in Junos OS Release 16.1R3.
Support for ACX Series added in Junos OS Release 17.1R1.
Description Specify the number of unknown messages per minute that the Path Computation Client
(PCC) can receive at maximum after which the PCEP session is closed.
Options messages-per-minute—Number of unknown messages per minute that the PCC can
receive at maximum after which the PCEP session is closed. Recommended value
is 5. If the number of unknown messages received by the PCC is greater than or equal
to the maximum number, the PCEP session is closed.
Range: 1 through 16384
Default: 0 (disabled or no limit)
Required Privilege
Level
routing—To view this statement in the configuration.
routing-controlTo add this statement to the configuration.
Related
Documentation
pce on page 1655
1605Copyright © 2017, Juniper Networks, Inc.