Except for jnxSoamDmHistoryStatsIndex, jnxSoamDmHistoryStatsEndTime,
jnxSoamDmHistoryStatsElapsedTime and jnxSoamDmHistoryStatsSuspect, each object
in this table applies only if the corresponding bit is set in
jnxSoamDmCfgMeasurementEnable. The rows and objects in this table are to be
persistent upon reboot or restart of a device.
Table 98: jnxSoamDmHistoryStatsTable
DescriptionObject IDObject
Specifies the index for the Measurement
Interval within this PM session.
Measurement Interval indexes are
assigned sequentially by the SNMP
Agent. The first Measurement Interval
that occurs after the session is started is
assigned index 1. Measurement Intervals
for FLR (stored in this table) are based
on iterator count and are indexed
independently of Measurement Intervals
for availability
Referential integrity is necessary, i.e., the
index needs to be persistent upon a
reboot or restart of a device. The index is
never reused while this session is active
until it wraps to zero. The index value
keeps increasing up to that time.
jnxSoamDmHistoryStatsEntry 1jnxSoamDmHistoryStatsIndex
Specifies the time at which the
Measurement Interval ended.
jnxSoamDmHistoryStatsEntry 2jnxSoamDmHistoryStatsEndTime
Specifies the length of time that the
Measurement Interval ran for, in 0.01
seconds.
jnxSoamDmHistoryStatsEntry 3jnxSoamDmHistoryStatsElapsedTime
Indicates whether the Measurement
Interval has been marked as suspect. The
object is set to true when there is a
discontinuity in the performance
measurements during the Measurement
Interval. Conditions for a discontinuity
include, but are not limited to the
following:
1—The local time-of-day clock is adjusted
by at least 10 seconds
2—The conducting of a performance
measurement is halted before the current
Measurement Interval is completed
3—A local test, failure, or reconfiguration
that disrupts service
jnxSoamDmHistoryStatsEntry 4jnxSoamDmHistoryStatsSuspect
Copyright © 2017, Juniper Networks, Inc.1212
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals