Page #1916 background imageLoading...
Page #1916 background image
T4000 Type 5 FPCs are required to be present on the router. If there are any other FPCs
(apart from T4000 Type 5 FPCs) on the T4000 router, such FPCs become offline, and
FPC misconfiguration alarms are generated. The show chassis alarm command output
displays FPC misconfiguration (FPC fpc-slot misconfig) as the reason for the generation
of the alarms.
user@host> show chassis alarms
2 alarms currently active
Alarm time Class Description
2011-10-22 10:10:47 PDT Major FPC 1 misconfig
2011-10-22 10:10:46 PDT Major FPC 0 misconfig
show chassis alarms (Backup Routing Engine)
user@host> show chassis alarms
2 alarms are currently active
Alarm time Class Description
2005-04-07 10:12:22 PDT Minor Host 1 Boot from alternate media
2005-04-07 10:11:54 PDT Major Host 1 compact-flash missing in Boot List
show chassis alarms (EX Series Switch)
user@switch> show chassis alarms
4 alarms currently active
Alarm time Class Description
2014-03-12 15:36:09 UTC Minor Require a Fan Tray upgrade
2014-03-12 15:00:02 UTC Major PEM 0 Input Failure
2014-03-12 15:00:02 UTC Major PEM 0 Not OK
2014-03-12 14:59:51 UTC Minor Host 1 Boot from alternate media
show chassis alarms (Alarms Active on the QFX Series and OCX Series Switches)
user@switch> show chassis alarms
1 alarms currently active
Alarm time Class Description
2012-03-05 2:10:24 UTC Major FPC 0 PEM 0 Airflow not matching Chassis Airflow
show chassis alarms node-device (Alarms Active on the QFabric System)
user@switch> show chassis alarms node-device Test
node-device ED3694
3 alarms currently active
Alarm time Class Description
2011-08-24 16:04:15 UTC Major Test:fte-0/1/2: Link down
2011-08-24 16:04:14 UTC Major Test:fte-0/1/0: Link down
2011-08-24 14:21:14 UTC Major Test PEM 0 is not supported/powered
show chassis alarms (Alarms Active on the QFabric System)
user@switch> show chassis alarms
IC-1:
--------------------------------------------------------------------------
1 alarms currently active
Alarm time Class Description
2011-08-24 16:04:15 UTC Minor Backup RE Active
Test:
--------------------------------------------------------------------------
Copyright © 2017, Juniper Networks, Inc.1858
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals