user@host> show chassis synchronization clock-module
re0:
--------------------------------------------------------------------------
Clock Synchronization Status :
Clock module on CB 0
Current state : Online - Master
Current clock state : locked to fpc-12
Selected for : 7 seconds
Selected since : 2016-08-16 09:39:07 PDT
Deviation (in ppm) : 10.00
Last deviation (in ppm): 8.75
Configured sources
Source Priority Deviation Last deviation Status
(in ppm) (in ppm)
fpc-12 primary 10.00 8.75 in-use#
show chassis synchronization extensive (ACX Series Routers)
user@host> show chassis synchronization extensive
Current clock status : Locked
Clock locked to : Primary
SNMP trap status : Enabled
Configured sources:
Interface : ge-0/0/7
Status : Secondary Index : 136
Clock source state : Clk qualified Priority : 3
Configured QL : SEC ESMC QL : PRC
Clock source type : ifd Clock Event : Clock qualified
Interface State : Up,sec,ESMC Rx(SSM 0x2),ESMC TX(QL PRC/SSM 0x2),
Interface : ge-0/1/1
Status : Primary Index : 138
Clock source state : Clk qualified Priority : 2
Configured QL : SEC ESMC QL : PRC
Clock source type : ifd Clock Event : Clock locked
Interface State : Up,pri,ESMC Rx(SSM 0x2),ESMC TX(QL DNU/SSM 0xf)
show chassis synchronization extensive (ACX500 Series Routers)
user@host> show chassis synchronization extensive
Current clock status : Locked
Clock locked to : Primary
Configured ports:
Name : gnss
Current ToD : Mon Aug 10 08:50:52 2015
Last ToD update : Mon Aug 10 08:50:51 2015
GPS receiver status : Synchronized
UTC Pending : FALSE
UTC Offset : 36
One PPS status : Active
2391Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands