95
SIB 0 64 70 76 72 87 84
95
SIB 0 ASIC Junction 63 68 75 70 105 100
107
SIB 2 64 70 76 72 87 84
95
SIB 2 ASIC Junction 63 68 75 70 105 100
107
SIB 3 64 70 76 72 87 84
95
SIB 3 ASIC Junction 63 68 75 70 105 100
107
show chassis temperature-thresholds (QFX3500 Switch and QFX3600)
user@switch> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm
(degrees C) (degrees C) (degrees C)
Item Normal High Normal Bad fan Normal Bad fan
rmal
FPC Sensor TopLeft I 48 56 53 43 56 46
FPC Sensor TopRight I 46 54 51 41 54 44
FPC Sensor TopLeft E 58 65 62 52 65 55
FPC Sensor TopRight E 56 64 61 51 64 54
FPC Sensor TopMiddle I 58 64 61 51 64 54
FPC Sensor TopMiddle E 67 74 71 61 74 64
FPC Sensor Bottom I 59 67 64 54 67 57
FPC Sensor Bottom E 66 73 70 60 73 63
FPC Sensor Die Temp 69 75 72 62 75 65
FPC Sensor Mgmnt Brd I 46 54 51 41 54 44
FPC Sensor Switch I 56 63 60 50 63 53
show chassis temperature-thresholds interconnect-device (QFabric System)
user@switch> show chassis temperature-thresholds interconnect-device interconnect1
temperature-thresholds interconnect-device interconnect1
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
show chassis temperature-thresholds (PTX5000 Packet Transport Router)
user@switch> show chassis temperature-thresholds
user@switch> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm Fire
Shutdown
(degrees C) (degrees C) (degrees C)
(degrees C)
Item Normal High Normal Bad fan Normal Bad fan
Normal
Routing Engine 0 80 90 95 85 105 95
115
CB 0 Exhaust A 60 65 78 75 85 80
95
CB 0 Exhaust B 60 65 78 75 85 80
95
CB 1 Exhaust A 60 65 78 75 85 80
95
2417Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands