115
SIB 6 Exhaust 60 65 78 75 85 80
95
SIB 6 Junction 75 80 90 85 105 95
115
SIB 7 Exhaust 60 65 78 75 85 80
95
SIB 7 Junction 75 80 90 85 105 95
115
SIB 8 Exhaust 60 65 78 75 85 80
95
SIB 8 Junction 75 80 90 85 105 95
115
show chassis temperature-thresholds (PTX1000 Packet Transport Router)
user@host> show chassis temperature-thresholds
Fan speed Yellow alarm Red alarm Fire
Shutdown
(degrees C) (degrees C) (degrees C)
(degrees C)
Item Normal High Normal Bad fan Normal Bad fan
Normal
FPC 0 Intake Temp Sensor 30 65 65 65 70 70
75
FPC 0 Exhaust Temp Sensor 30 65 65 65 70 70
75
FPC 0 Mezz Temp Sensor 0 30 65 65 65 70 70
75
FPC 0 Mezz Temp Sensor 1 30 65 65 65 70 70
75
FPC 0 PE2 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PE1 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PF0 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PE0 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PE5 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PE4 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PF1 Temp Sensor 50 90 90 90 100 100
103
FPC 0 PE3 Temp Sensor 50 90 90 90 100 100
103
FPC 0 CPU Die Temp Sensor 50 90 90 90 100 100
103
FPC 0 OCXO Temp Sensor 50 90 90 90 100 100
103
show chassis temperature-thresholds (MX Routers with Media Services Blade [MSB])
user@switch> show chassis temperature-thresholds
2419Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands