Table 144: ATM show interfaces Output Fields (continued)
Level of OutputField DescriptionField Name
detail extensiveCoS queue number and its associated user-configured forwarding class name.
• Queued packets—Number of queued packets.
• Transmitted packets—Number of transmitted packets.
• Dropped packets—Number of packets dropped by the ASIC's RED mechanism.
NOTE: Physical interface queue counters of ATM2 PICs displayed by the show
interfaces at-fpc/pic/port detail command show the packet forwarding stream
statistics associated with the ATM2 ports. Since multiple ports of the ATM2
PICs (except for the ATM2 dual-port OC12) share one packet forwarding stream,
the physical interface queue counters reflect the aggregate of ATM2 port
statistics.
Queue counters
detail extensive noneSONET media-specific defects that prevent the interface from passing packets.
When a defect persists for a certain period, it is promoted to an alarm. Based
on the router configuration, an alarm can ring the red or yellow alarm bell on
the router or light the red or yellow alarm LED on the craft interface. See these
fields for possible alarms and defects: SONET PHY, SONET section, SONET line,
and SONET path.
SONET alarms
SONET defects
extensiveCounts of specific SONET errors with detailed information.
• Seconds—Number of seconds the defect has been active.
• Count—Number of times that the defect has gone from inactive to active.
• State—State of the error. State other than OK indicates a problem.
Subfields are:
• PLL Lock—Phase-locked loop
• PHY Light—Loss of optical signal
SONET PHY
extensiveCounts of specific SONET errors with detailed information.
• Seconds—Number of seconds the defect has been active.
• Count—Number of times that the defect has gone from inactive to active.
• State—State of the error. State other than OK indicates a problem.
Subfields are:
• BIP-B1—Bit interleaved parity for SONET section overhead
• SEF—Severely errored framing
• LOL—Loss of light
• LOF—Loss of frame
• ES-S—Errored seconds (section)
• SES-S—Severely errored seconds (section)
• SEFS-S—Severely errored framing seconds (section)
SONET section
2475Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands