Table 149: Link Services show interfaces Output Fields
Level of OutputField DescriptionField Name
Physical Interface
All levelsName of the physical interface.Physical interface
All levelsState of the interface. Possible values are described in the “Enabled Field”
section under Common Output Fields Description.
Enabled
detail extensive nonePhysical interface's index number, which reflects its initialization sequence.Interface index
detail extensive noneSNMP index number for the physical interface.SNMP ifIndex
detail extensiveUnique number for use by Juniper Networks technical support.Generation
All levelsEncapsulation being used on the physical interface:
Multilink-Frame-Relay-UNI-NNI (default), LinkService, Frame-relay,
Frame-relay-ccc, or Frame-relay-tcc.
Link-level type
All levelsMaximum transmission unit size on the physical interface.MTU
All levelsInformation about the physical device. Possible values are described in the
“Device Flags” section under Common Output Fields Description.
Device flags
All levelsInformation about the interface. Possible values are described in the “Interface
Flags” section under Common Output Fields Description.
Interface flags
detail extensive noneDate, time, and how long ago the interface went from down to up. The format
is Last flapped: year-month-day hour:minute:second timezone (hour:minute:second
ago) . For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago).
Last flapped
detail extensiveTime when the statistics for the interface were last set to zero.Statistics last
cleared
All levelsInformation about the link. Possible values are described in the “Link Flags”
section under Common Output Fields Description.
Link flags
detail extensiveCurrent interface hold time up and hold time down, in milliseconds, in the format
Up n ms, Down n ms.
Hold-times
2587Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals