EasyManua.ls Logo

Juniper ACX2000 - Page 2691

Juniper ACX2000
3270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 152: show interfaces (Gigabit Ethernet) Output Fields (continued)
Level of OutputField DescriptionField Name
extensive(10-Gigabit Ethernet interfaces, WAN PHY mode) SONET error information:
Seconds—Number of seconds the defect has been active.
Count—Number of times that the defect has gone from inactive to active.
StateState of the error. Any state other than OK indicates a problem.
Subfields are:
BIP-B1—Bit interleaved parity for SONET section overhead
SEF—Severely errored framing
LOL—Loss of light
LOF—Loss of frame
ES-S—Errored seconds (section)
SES-S—Severely errored seconds (section)
SEFS-S—Severely errored framing seconds (section)
WIS section
extensive(10-Gigabit Ethernet interfaces, WAN PHY mode) Active alarms and defects,
plus counts of specific SONET errors with detailed information:
Seconds—Number of seconds the defect has been active.
Count—Number of times that the defect has gone from inactive to active.
StateState of the error. Any state other than OK indicates a problem.
Subfields are:
BIP-B2—Bit interleaved parity for SONET line overhead
REI-L—Remote error indication (near-end line)
RDI-L—Remote defect indication (near-end line)
AIS-L—Alarm indication signal (near-end line)
BERR-SF—Bit error rate fault (signal failure)
BERR-SD—Bit error rate defect (signal degradation)
ES-L—Errored seconds (near-end line)
SES-L—Severely errored seconds (near-end line)
UAS-L—Unavailable seconds (near-end line)
ES-LFE—Errored seconds (far-end line)
SES-LFE—Severely errored seconds (far-end line)
UAS-LFE—Unavailable seconds (far-end line)
WIS line
2633Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands

Table of Contents

Other manuals for Juniper ACX2000