user@host# set max-announce-interval max-announce-interval-value
6. (Optional) Specify the maximum log mean interval between delay-response
messages—from 7 through 4. The default value is 4.
[edit protocols ptp master]
user@host# set max-delay-response-interval max-delay-response-interval-value
7. (Optional) Specify the maximum log mean interval between synchronization
messages—from 7 through 4. The default value is 4.
[edit protocols ptp master]
user@host# set max-sync-interval max-sync-interval-value
8. (Optional) Specify the minimum log mean interval between announce messages—from
0 through 4. The default value is 0.
[edit protocols ptp master]
user@host# set min-announce-interval min-announce-interval
9. (Optional) Specify the minimum log mean interval between delay-response
messages—from 7 through 4. The default value is 7.
[edit protocols ptp master]
user@host# set min-delay-response-interval min-delay-response-interval
10. (Optional) Specify the minimum log mean interval between synchronization
messages—from 7 through 4. The default value is 7.
[edit protocols ptp master]
user@host# set min-sync-interval min-sync-interval-value
11. (Optional) Specify the log mean interval between synchronization messages—from
7 through 4. The default value is –6. This configuration is used for manual clock
clients. The master boundary clock sends synchronization messages to manual clock
clients as specified in the syn-interval-value statement.
[edit protocols ptp master]
user@host# set sync-interval sync-interval-value
After you have configured the PTP master boundary clock parameters, enter the commit
command from configuration mode. To complete the configuration of the master
boundary clock, complete “Configuring the PTP over Ethernet Master Boundary Clock
Interface” on page 277.
Copyright © 2017, Juniper Networks, Inc.276
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals