Table 91: jnxSoamLmCfgTable (continued)
DescriptionObject IDObject
Specifies the type of Loss Measurement to be performed.
lmLmm(1)—LMM SOAM PDU generated and received
LMR responses tracked
lmSlm(2)—SLM SOAM PDU generated and received
SLR responses tracked
lmCcm(3)—CCM SOAM PDU generated and received
CCM PDUs tracked
The lmSlm value is required. The lmLmm and lmCcm
values are optional.
The lmCcm loss measurement values are only valid for a
point-to-point MEG. Multipoint MEGs may give unreliable
loss measurements. This object can only be written at row
creation time and cannot be modified once it has been
created.
JnxSoamLmCfgEntry
2
jnxSoamLmCfgType
Indicates the version of the PDUs used to perform Loss
Measurement.
The value is placed in the Version field of the PDU and
indicates that the PDU format used is the format defined
in Y.1731 with that version.
The exact PDUs to use are specified by this object in
combination with jnxSoamLmCfgType.
This object can only be written at row creation time and
cannot be modified once it has been created.
JnxSoamLmCfgEntry
3
jnxSoamLmCfgVersion