Table 91: jnxSoamLmCfgTable (continued)
DescriptionObject IDObject
Specifies the fixed start date/time for the SOAM Loss
Measurement session. This object is used only used if
jnxSoamLmStartTimeType is 'fixed' and is ignored
otherwise.
The default value is year 0000, month 01, day 01, time
00:00:00.00.
This object can only be written at row creation time and
cannot be modified once it has been created.
JnxSoamLmCfgEntry
16
jnxSoamLmCfgFixedStartDateAndTime
Specifies the relative start time, from the current system
time, for the SOAM LM session. This object is used only if
jnxSoamLmStartTimeType is 'relative' and is ignored
otherwise.
This object can only be written at row creation time and
cannot be modified once it has been created.
JnxSoamLmCfgEntry
17
jnxSoamLmCfgRelativeStartTime
Specifies a configurable repetition time between
Measurement Intervals in a Loss Measurement session,
in seconds.
If the value is 0 (none), there is no time gap between the
end of one Measurement Interval and the start of a new
Measurement Interval. This is the normal usage case.
If the value is greater than 0 but less than or equal to the
measurement interval, an error is returned.
If the value is greater than one Measurement Interval there
is time gap between the end of one Measurement Interval
and the start of the next Measurement Interval. The
repetition time specifies the time between the start of
consecutive Measurement Intervals; hence the gap
between the end of one Measurement Interval and the
start of the next is equal to the difference between the
repetition time and the measurement interval. During this
gap, no SOAM PDUs are sent for this session and no
measurements are made.
This object can only be written at row creation time and
cannot be modified once it has been created.
JnxSoamLmCfgEntry
18
jnxSoamLmCfgRepetitionTime
Copyright © 2017, Juniper Networks, Inc.1182
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals