user@host# edit ge-0/0/4
3. Configure a logical unit and specify the protocol family as inet.
[edit interfaces ge-0/0/4]
user@host# edit unit 0 family inet
4. Specify the address for the logical interface.
[edit interfaces ge-0/0/4 unit 0 family inet]
user@host# set address 200.0.0.2/24
5. Enter the up command to go the previous level in the configuration hierarchy.
[edit interfaces ge-0/0/4 unit 0 family inet]
user@host# up
6. Go to the top level of the configuration command mode.
[edit interfaces ge-0/0/4 unit 0]
user@host# top
7. In configuration mode, go to the [edit services] hierarchy level.
[edit]
user@host# edit services
8. Configure a real-time performance monitoring service (RPM) instance.
[edit services]
user@host# edit rpm
9. Configure an RFC 2544-based benchmarking test for the RPM instance.
[edit services rpm]
user@host# edit rfc2544-benchmarking
10. Define a name for the test—for example, test1. The test name identifier can be up
to 32 characters in length.
[edit services rpm rfc2544-benchmarking]
user@host# edit tests test-name test1
11. Specify the logical interface, ge-0/0/4.1, on which the RFC 2544-based
benchmarking test is run.
[edit services rpm rfc2544-benchmarking tests test-name test1]
user@host# set test-interface ge-0/0/4.1
12. Specify reflect as the test mode for the packets that are sent during the
benchmarking test.
[edit services rpm rfc2544-benchmarking tests test-name test1]
Copyright © 2017, Juniper Networks, Inc.1364