user@host# set vlan-tagging
4. Configure a logical unit for the interface.
[edit interfaces ge-0/0/4]
user@host# edit unit 0
5. Specify the encapsulation for Ethernet VLAN circuits.
[edit interfaces ge-0/0/4 unit 0]
user@host# set encapsulation vlan-ccc
6. Configure the VLAN ID as 101 on the logical interface.
[edit interfaces ge-0/0/4 unit 0]
user@host# set vlan-id 101
7. Go to the top level of the configuration command mode.
[edit interfaces ge-0/0/4 unit 0]
user@host# top
8. In configuration mode, go to the [edit services] hierarchy level.
[edit]
user@host# edit services
9. Configure a real-time performance monitoring service (RPM) instance.
[edit services]
user@host# edit rpm
10. Configure an RFC 2544-based benchmarking test for the RPM instance.
[edit services rpm]
user@host# edit rfc2544-benchmarking
11. Define a name for the test—for example, test1. The test name identifier can be up
to 32 characters in length.
[edit services rpm rfc2544-benchmarking]
user@host# edit tests test-name test1
12. Specify the logical interface on which the RFC 2544-based benchmarking test is
run.
[edit services rpm rfc2544-benchmarking tests test-name test1]
user@host# set test-interface ge-0/0/4.1
13. Specify reflect as the test mode for the packets that are sent during the
benchmarking test.
[edit services rpm rfc2544-benchmarking tests test-name test1]
1381Copyright © 2017, Juniper Networks, Inc.
Chapter 37: Configuring RFC 2544-Based Benchmarking Tests