Table 121: show chassis environment Output Fields
Field DescriptionField Name
Information about the category or class of chassis component:
• Power: Power information:
• (M5, M10, M20, and M40 routers and EX Series switches only) Power supply status: OK, Testing,
(during initial power-on), Failed, or Absent.
• (M7i, M10i, M40e, M120, M160, M320, and T Series routers and EX Series switches only) Power
Entry Modules status: OK, Testing, (during initial power-on), Check, Failed, or Absent.
• (PTX Series only) Power information is reported in PDU or PSM combinations. The status is: OK,
Testing, (during initial power-on), Check, Failed, or Absent.
• Temp: Temperature of air flowing through the chassis in degrees Celsius (C) and Fahrenheit (F).
• On PTX Series Packet Transport Routers and MX2010, MX2020, and MX2008 Routers, multiple
cooling zones are supported. FRU temperatures in each zone are coordinated with the fan speed
of fan trays in those zones.
• EX2200 switches have a side-to-rear cooling system. The Local Intake temperature is measured
by the sensor on the right side of the chassis, and the Remote Intake temperature is measured
by the sensor on the left side of the chassis.
• Pic: On ACX4000 routers, multiple temperature channels on a MIC. The status is: OK and the
Measurement is in degrees Celsius (C) and Fahrenheit (F).
• Fan: Fan status: OK, Testing (during initial power-on), Failed, or Absent.
On PTX Series Packet Transport Routers and MX2010, MX2020, and MX2008 Routers, multiple
fan trays are supported. Fan status is reported in Fan Tray or Fan combinations. Measurement
indicates actual fan RPM (PTX and MX2010, MX2020, and MX2008 Routers only).
• Misc: Information about other components of the chassis.
• On some routers, this field indicates the status of one or more additional components.
• On the M40e, M160, and M320 router, Misc includes CIP (Connector Interface Panel). OK indicates
that the CIP is present. Absent indicates that the CIP is not present.
• On T Series routers, Misc includes CIP and SPMB (Switch Processor Mezzanine Board). OK
indicates that the CIP or SPMB is present. Absent indicates that the CIP or SPMB is not present.
• On PTX Series Packet Transport Routers, Misc includes the SPMB (Switch Processor Mezzanine
Board). The SPMB is located on the control boards. OK indicates that the control board is present.
Absent indicates that the control board is not present.
Class
(MX2010, MX2020, and MX2008 Routers) Information about the chassis component: Routing Engines,
Controls Boards (CBs), Switch Fabric Boards (SFBs), PICs, Flexible PIC Concentrators (FPCs), and
Adapter Cards (ADCs).
(MX104 Routers) Information about the chassis components: Routing Engines, Control Board (CB),
Power Entry Module (PEM), and Compact Forwarding Engine Board (AFEB).
(QFabric Systems) Information about the chassis component: Control Boards, Routing Engines,
Flexible PIC Concentrators (FPCs), and Power Entry Modules (PEMs), Node Devices, and Interconnect
Devices.
(QFX Series) Information about the chassis component: Flexible PIC Concentrators (FPCs), and
Power Entry Modules (PEMs).
Item
1891Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands