Table 121: show chassis environment Output Fields (continued)
Field DescriptionField Name
(MX104, MX2010, MX2020, and MX2008 Routers) Status of the specified chassis component. For
example, if the Class is Fan, the fan status can be:
• OK: The fans are operational.
• Testing: The fans are being tested during initial power-on.
• Failed: The fans have failed or the fans are not spinning.
• Absent: The fan tray is not installed.
If the Class is Power, the power supply status can be:
• OK: The power component is operational.
• Testing: The power component is being tested during initial power-on.
• Check: There is insufficient power---that is, fewer than the minimum required feeds are connected.
• Failed: The inputs leads have failed.
• Absent: The power component is not installed.
Status
(MX104, MX2010, MX2020, and MX2008 Routers) Dependant on the Class. For example, if the Class
is Temp, indicates the temperature in degree Celsius and degrees Fahrenheit. If the Class is Fan,
indicates actual fan RPM.
Measurement
Sample Output
show chassis environment (M5 Router)
user@host> show chassis environment
Class Item Status Measurement
Power Power Supply A OK
Power Supply B Absent
Temp FPC 0 OK 30 degrees C / 86 degrees F
FEB OK 33 degrees C / 91 degrees F
PS Intake OK 27 degrees C / 80 degrees F
PS Exhaust OK 27 degrees C / 80 degrees F
Routing Engine OK 34 degrees C / 93 degrees F
Fans Left Fan 1 OK Spinning at normal speed
Left Fan 2 OK Spinning at normal speed
Left Fan 3 OK Spinning at normal speed
Left Fan 4 OK Spinning at normal speed
Misc Craft Interface OK
show chassis environment (M7i Router)
user@host> show chassis environment
Class Item Status Measurement
Power Power Supply 0 OK
Power Supply 1 Absent
Temp Intake OK 22 degrees C / 71 degrees F
FPC 0 OK 23 degrees C / 73 degrees F
Power Supplies OK 23 degrees C / 73 degrees F
CFEB Intake OK 24 degrees C / 75 degrees F
CFEB Exhaust OK 29 degrees C / 84 degrees F
Routing Engine OK 26 degrees C / 78 degrees F
Fans Fan 1 OK Spinning at normal speed
Copyright © 2017, Juniper Networks, Inc.1892