show chassis environment (EX8216 Switch)
user@switch> show chassis environment
Class Item Status Measurement
Power PSU 0 OK
PSU 1 OK
PSU 2 OK
PSU 3 Check
PSU 4 Absent
PSU 5 Absent
Temp CB 0 Intake OK 23 degrees C / 73 degrees F
CB 0 Exhaust OK 26 degrees C / 78 degrees F
CB 1 Intake OK 22 degrees C / 71 degrees F
CB 1 Exhaust OK 25 degrees C / 77 degrees F
FPC 4 Intake OK 49 degrees C / 120 degrees F
FPC 4 Exhaust OK 59 degrees C / 138 degrees F
SIB 5 Intake OK 25 degrees C / 77 degrees F
SIB 5 Exhaust OK 35 degrees C / 95 degrees F
SIB 6 Intake OK 25 degrees C / 77 degrees F
SIB 6 Exhaust OK 38 degrees C / 100 degrees F
Fans Top Fan 1 OK Spinning at normal speed
Top Fan 2 OK Spinning at normal speed
Top Fan 3 OK Spinning at normal speed
Top Fan 4 OK Spinning at normal speed
Top Fan 5 OK Spinning at normal speed
Top Fan 6 OK Spinning at normal speed
Top Fan 7 OK Spinning at normal speed
Top Fan 8 OK Spinning at normal speed
Top Fan 9 OK Spinning at normal speed
Bottom Fan 1 OK Spinning at normal speed
Bottom Fan 2 OK Spinning at normal speed
Bottom Fan 3 OK Spinning at normal speed
Bottom Fan 4 OK Spinning at normal speed
Bottom Fan 5 OK Spinning at normal speed
Bottom Fan 6 OK Spinning at normal speed
Bottom Fan 7 OK Spinning at normal speed
Bottom Fan 8 OK Spinning at normal speed
Bottom Fan 9 OK Spinning at normal speed
show chassis environment (EX9200 Switch)
user@switch> show chassis environment
Class Item Status Measurement
Temp PEM 0 Check
PEM 1 OK 40 degrees C / 104 degrees F
PEM 2 OK 40 degrees C / 104 degrees F
PEM 3 Absent
Routing Engine 0 OK 35 degrees C / 95 degrees F
Routing Engine 0 CPU OK 33 degrees C / 91 degrees F
Routing Engine 1 OK 38 degrees C / 100 degrees F
Routing Engine 1 CPU OK 33 degrees C / 91 degrees F
CB 0 Intake OK 35 degrees C / 95 degrees F
CB 0 Exhaust A OK 33 degrees C / 91 degrees F
CB 0 Exhaust B OK 40 degrees C / 104 degrees F
CB 0 ACBC OK 39 degrees C / 102 degrees F
CB 0 XF A OK 49 degrees C / 120 degrees F
CB 0 XF B OK 46 degrees C / 114 degrees F
CB 1 Intake OK 37 degrees C / 98 degrees F
CB 1 Exhaust A OK 32 degrees C / 89 degrees F
CB 1 Exhaust B OK 39 degrees C / 102 degrees F
Copyright © 2017, Juniper Networks, Inc.1944
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals