CB 1 ACBC OK 41 degrees C / 105 degrees F
CB 1 XF A OK 49 degrees C / 120 degrees F
CB 1 XF B OK 49 degrees C / 120 degrees F
FPC 2 Intake OK 37 degrees C / 98 degrees F
FPC 2 Exhaust A OK 40 degrees C / 104 degrees F
FPC 2 Exhaust B OK 34 degrees C / 93 degrees F
FPC 2 LU 0 TCAM TSen OK 44 degrees C / 111 degrees F
FPC 2 LU 0 TCAM Chip OK 48 degrees C / 118 degrees F
FPC 2 LU 0 TSen OK 44 degrees C / 111 degrees F
FPC 2 LU 0 Chip OK 60 degrees C / 140 degrees F
FPC 2 MQ 0 TSen OK 44 degrees C / 111 degrees F
FPC 2 MQ 0 Chip OK 51 degrees C / 123 degrees F
FPC 3 Intake OK 39 degrees C / 102 degrees F
FPC 3 Exhaust A OK 51 degrees C / 123 degrees F
[...Output truncated...]
Fans Top Rear Fan OK Spinning at intermediate-speed
Bottom Rear Fan OK Spinning at intermediate-speed
Top Middle Fan OK Spinning at intermediate-speed
Bottom Middle Fan OK Spinning at intermediate-speed
Top Front Fan OK Spinning at intermediate-speed
Bottom Front Fan OK Spinning at intermediate-speed
show chassis environment (QFX Series and OCX Series)
user@switch> show chassis environment
Class Item Status Measurement
Power FPC 0 Power Supply 0 OK
FPC 0 Power Supply 1 OK
Temp FPC 0 Sensor TopLeft I OK 26 degrees C / 78 degrees F
FPC 0 Sensor TopRight I OK 24 degrees C / 75 degrees F
FPC 0 Sensor TopLeft E OK 30 degrees C / 86 degrees F
FPC 0 Sensor TopRight E OK 30 degrees C / 86 degrees F
FPC 0 Sensor TopMiddle I OK 30 degrees C / 86 degrees F
FPC 0 Sensor TopMiddle E OK 38 degrees C / 100 degrees F
FPC 0 Sensor Bottom I OK 34 degrees C / 93 degrees F
FPC 0 Sensor Bottom E OK 38 degrees C / 100 degrees F
FPC 0 Sensor Die Temp OK 38 degrees C / 100 degrees F
FPC 0 Sensor Mgmnt Brd I OK 24 degrees C / 75 degrees F
FPC 0 Sensor Switch I OK 28 degrees C / 82 degrees F
Fans FPC 0 Fan 1 (left) Failed
FPC 0 Fan 2 (right) OK Spinning at normal speed
FPC 0 Fan 3 (middle) OK Spinning at normal speed
show chassis environment interconnect-device (QFabric System)
user@switch> show chassis environment interconnect-device IC-A0004
Class Item Status Measurement
CB 0
CB 0 L Intake OK 30 degrees C / 86 degrees F
CB 0 R Intake OK 31 degrees C / 87 degrees F
CB 0 L Exhaust OK 32 degrees C / 89 degrees F
CB 0 R Exhaust OK 33 degrees C / 91 degrees F
Routing Engine 0 CPU temp OK 51 degrees C / 123 degrees F
CB 1
CB 1 L Intake OK 27 degrees C / 80 degrees F
CB 1 R Intake OK 29 degrees C / 84 degrees F
CB 1 L Exhaust OK 31 degrees C / 87 degrees F
CB 1 R Exhaust OK 32 degrees C / 89 degrees F
1945Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals