Table 205: show protection-group ethernet-ring statistics Output Fields
Field DescriptionField Name
Name of the protection group for which statistics are displayed.Ethernet Ring Statistics for PG
Number of times Ring Automatic Protection Switching (RAPS)
message transmission event occurred locally. This field is
applicable only to MX Series routers.
RAPS event sent
Number of RAPS messages received and processed by ERP
state-machine and which resulted in state transition. This field
is applicable only to MX Series routers.
RAPS event received
Number of times a signal failure has occurred locally.Local SF
Number of times a signal failure has occurred anywhere else on
the ring.
Remote SF
Number of times a No Request event has occurred on the ring.
This field is applicable only to EX Series switches.
NR event
Number of times a No Request event has occurred locally. This
field is applicable only to MX Series routers.
NR event sent
Number of times a No Request event has occurred anywhere
else on the ring. This field is applicable only to MX Series routers.
NR event received
Number of times a No Request, Ring Blocked event has occurred
on the ring. This field is applicable only to EX Series switches.
NR-RB event
Number of times a No Request, Ring Blocked event has occurred
locally. This field is applicable only to MX Series routers.
NR-RB event sent
Number of times a No Request, Ring Blocked event has occurred
anywhere else on the ring. This field is applicable only to MX
Series routers.
NR-RB event received
Number of times flush-event RAPS message transmission event
occurred locally. This field is applicable only to MX Series routers.
Flush event sent
Number of flush-event RAPS messages received and processed
by the ring instance control process. This field is applicable only
to MX Series routers.
Flush event received
Number of times a forced switch event has occurred locally. This
field is applicable only to MX Series routers.
Local FS event sent
Number of times a forced switch event has occurred anywhere
else on the ring. This field is applicable only to MX Series routers.
Remote FS event received
Number of times a manual switch event has occurred locally.
This field is applicable only to MX Series routers.
Local MS event sent
Copyright © 2017, Juniper Networks, Inc.2928
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals