Table 209: show ptp global-information Output Fields (continued)
Field DescriptionField Name
Display the status of the transparent clock operation. The following status would be displayed:
• N/A—Transparent clock is not configured.
• Active—Transparent clock is configured and working properly.
• sync-in-progress—This is a temporary state. During startup, all the PHYs are synchronized with each
other. This status can also occur when a new MIC is plugged in to the router (for example, ACX4000)
and all the PHYs go through the synchronization cycle again.
NOTE: Transparent clock operation is disabled during the synchronization of PHYs.
• Inactive—Transparent clock is configured but not working properly. This would indicate a hardware
error in PHY timestamping logic.
Transparent-clock-status
Sample Output
show ptp global-information
user@host> show ptp global-information
PTP Global Configuration:
Profile Type : G.8275.1
Domain number : 0
Clock mode : Boundary
PTP Profile Type : -
Priority Level1 : 128
Priority Level2 : 30
Unicast Negotiation : Enabled
ESMC QL From Clock Class : Disabled
Clock Class/ESMC QL : -
SNMP Trap Status : Enabled
Transparent-clock-config : DISABLED
Transparent-clock-status : N/A
Slave Parameters:
Sync Interval : -6 (64 packets per second - unicast request)
Delay Request Interval: -6 (64 packets per second - unicast request)
Announce Interval : 1 (1 packet every 2 seconds - unicast request)
Announce Timeout : 3
Grant Duration : 300
Master Parameters:
Sync Interval : -6 (64 packets per second)
Announce Interval : 1 (1 packet every 2 seconds)
Min Announce Interval : 0 (1 packet per second)
Max Announce Interval : 1 (1 packet every 2 seconds)
Min Sync Interval : -7 (128 packets per second)
Max Sync Interval : 4 (1 packet every 16 seconds)
Min Delay Response Interval : -7 (128 packets per second)
Max Delay Response Interval : 4 (1 packet every 16 seconds)
Clock Step : one-step
Arbitrary Mode : FALSE
Holdover In Specification Time : 86400
Number of Slaves : 1
Number of Masters : 1
Number of Stateful : 2
2941Copyright © 2017, Juniper Networks, Inc.
Chapter 42: Operational Commands

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals