Table 232: show services rpm rfc2544-benchmarking test-id Output Fields
Level of OutputField DescriptionField Name
None specifiedDetails of the performed RFC 2544 benchmarking test.Test information
None specifiedUnique identifier configured for the test.Test id
None specifiedName configured for the test.Test name
None specifiedThe type of actual test run that is collected for the test, based on the configured
test type. Throughput-related, latency, frame-loss, or back-to-back
frames-related information is displayed for ACX Series routers. Reflected
packets-related information is displayed for MX104 Series routers.
Test type
None specifiedMode configured for the test on the router. Test modes are:
• Initiate-and-Terminate: Test frames are initiated from one end and terminated
at the same end. This mode requires a reflector to be configured at the peer
end to enable the test frames to be returned to the source. This mode is
supported only on ACX Series routers.
• Reflect: Test frames that originate from one end are reflected back to the
originator, such as IPv4 or Ethernet.
Test mode
None specifiedSize of the test packets in bytes. This field is valid only when the test mode is
Initiate-and-Terminate.
Test packet size
None specifiedState of the test that is in progress or active when the output is displayed. For
details about the states, see RFC 2544-Based Benchmarking Test States.
Test state
None specifiedIndicates whether the test is currently in progress or has been terminated.Status
None specifiedTime at which the test started in Coordinated Universal Time (UTC) format
(YYYY-MM-DD-HH:MM:SS).
Test start time
None specifiedTime at which the test completed.Test finish time
None specifiedDate, time, and how long ago the statistics for the test were cleared. The format
is year-month-day hour:minute:second:timezone (hour:minute:second ago). For
example, 2010-05-17 07:51:28 PDT (00:04:33 ago). If you did not clear the
statistics previously at any point, Never is displayed.
Counters last
cleared
detail(ACX Series routers only) Details of the specified test profileTest-profile
Configuration
detail(ACX Series routers only) Name of the configured test profile that contains the
parameters for the test
Test-profile name
detail(ACX Series routers only) Size of the test packets in bytesTest packet size
detail(ACX Series routers only) Theoretical maximum bandwidth configured for the
test. This value is typically set to the bandwidth of the server being tested. Valid
values are 1 Kbps through 1,000,000 Kbps (1 Gbps). The value defined is the
highest bandwidth value tested for this test.
Theoretical max
bandwidth
Copyright © 2017, Juniper Networks, Inc.3162
ACX Series Universal Access Router Configuration Guide

Table of Contents

Other manuals for Juniper ACX2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper ACX2000 and is the answer not in the manual?

Juniper ACX2000 Specifications

General IconGeneral
BrandJuniper
ModelACX2000
CategoryNetwork Router
LanguageEnglish

Related product manuals