2.21 Setting External Mixer
2-991
2
SCPI Device Message Details
[:SENSe]:MIXer:BIAS?
External Mixer Bias Query
Function
This command queries the current external mixer's bias current.
Query
[:SENSe]:MIXer:BIAS?
Response
<bias>
Parameter
<bias>
External mixer's bias current
Range 0.1 to 20.0 mA
Resolution 0.1 mA
Suffix code None, value is returned in mA units.
Details
This function is available when Option 044/045 is installed for MS2830A.
This function is available when Option 044/046 is installed for MS2840A.
One value is held per external mixer band.
When using High Performance Waveguide Mixer, the external mixer's
bias current is fixed to 0.0 mA.