EasyManua.ls Logo

Anritsu MS2840A - DISP:SPUR:SEGM;DISP:SPUR:SEGM?

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
Native Device Message Details
4-75
4
Native Device Message Details
DISP:SPUR:SEGM/DISP:SPUR:SEGM?
Displayed Segment
Function
This command specifies the segment to display the trace data in.
Command
DISP:SPUR:SEGM integer
Query
DISP:SPUR:SEGM?
Response
integer
Parameter
integer
Segment number
Range 1 to 20
Resolution 1
Details
A segment which is set to Off cannot be specified.
This command is not available during measurement and when Displayed
Segment Mode is Auto.
Example of Use
To specify 2 to the segment to display the trace data in.
DISP:SPUR:SEG 2
DISP:SPUR:SEG?
> 2