Chapter 2 SCPI Device Message Detail
2-814
:CALCulate:SPURious:MARKer:COUPle[:STATe] ON|OFF|1|0
Spurious Emission Couple Zone
Function
This command enables/disables the setting of the function that the same
value is automatically set to Zone Width in each marker.
Refer to
:CALCulate:MARKer:COUPle:ZONE[:STATe].
Related Command
This command has the same function as the following command.
:CALCulate:MARKer:COUPle:ZONE[:STATe]
:CALCulate:SPURious:MARKer:COUPle[:STATe]?
Spurious Emission Couple Zone Query
Function
This command queries On/Off of the function that the value is
automatically set to Zone Width in each marker.
Refer to
:CALCulate:MARKer:COUPle:ZONE[:STATe]?.
Related Command
This command has the same function as the following command.
:CALCulate:MARKer:COUPle:ZONE[:STATe]?