Chapter 2 SCPI Device Message Details
2-252
:INITiate[:IMMediate]
Initiate
Function
This command starts sweeping in the presently set sweep mode.
Command
:INITiate:[IMMediate]
Details
To read out the measurement results after executing this command,
perform the synchronization control using the “
*WAI
” command.
Example of Use
To start sweeping in the presently set sweep mode.
INIT:IMM
:INITiate:SWP
Single Sweep
Function
This command sets the sweep mode to single and starts single sweep.
Command
:INITiate:SWP
Details
Starting sweep with this function makes the following command wait
without being processed until sweep is finished.
Example of Use
To start single sweep.
INIT:SWP