2.17 Configuring Batch Measurement Settings
2-931
2
SCPI Device Message Details
:MEASure:BATCh:IM? <filename>,<spa_freq>[,<sg_freq>[,<device>]]
Transmit Intermodulation Batch Measure
Function
This command executes Transmit intermodulation measurement and
outputs the result based on the specified parameter list file.
Query
:MEASure:BATCh:IM?
<filename>,<spa_freq>[,<sg_freq>[,<device>]]
Response
Two values of ref_carrier_a are output when ACP Reference is BSIDes.
<ref_carrier_a>(,<ref_carrier_a>),<lower_offset_1_rel>,<
lower_offset_1_abs>,<upper_offset_1_rel>,<upper_offset_1
_abs>,<lower_offset_2_rel>,<lower_offset_2_abs>,<upper_o
ffset_2_rel>,<upper_offset_2_abs>,<lower_offset_3_rel>,<
lower_offset_3_abs>,<upper_offset_3_rel>,<upper_offset_3
_abs>,<spa_1_result>,<spa_2_result>
Parameter
<filename>
Parameter list file
Specify with any character string enclosed by
double quotes (" ") or single quotes (' ').
<spa_freq>
Center frequency of Spectrum Analyzer function
Range –100 MHz to +6.05 GHz (MS2690A)
–100 MHz to +13.6 GHz (MS2691A)
–100 MHz to +26.6 GHz (MS2692A)
Resolution 1 Hz
Suffix code HZ, KHZ, KZ, MHZ, MZ, GHZ, GZ
Hz is used when omitted.
MAXimum, MINimum and DEFault are not
available.
<sg_freq>
Frequency of Signal Generator
Range 125 MHz to 6 GHz
Resolution 0.01 Hz
Suffix code HZ, KHZ, KZ, MHZ, MZ, GHZ, GZ
Hz is used when omitted.
MAXimum, MINimum and DEFault are not
available.