2.14 Spurious Emission Measurement Function
2-761
2
SCPI Device Message Details
[:SENSe]:SPURious:POWer[:RF]:GAIN[:STATe]
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0
Spurious Emission Preamp On/Off
Function
This command sets the pre-amp of each segment to On/Off.
Command
[:SENSe]:SPURious:POWer[:RF]:GAIN[:STATe] <switch_n>
Parameter
<switch_n>
Pre-amp On/Off
ON|1
Sets Pre-amp to On
OFF|0
Sets Pre-amp to Off
Default Off
Details
[MS269xA]
When Option 008/108 6GHz Pre-amp is not installed, the pre-amp
setting is fixed to Off.
[MS2830A]
This command becomes unavailable when Option 008/108/068/168
Preamplifier is not installed.
[MS2840A]
This command becomes unavailable when Option
008/108/068/168/069/169 Preamplifier is not installed.
Example of Use
To set the pre-amp of each segment.
SPUR:POW:GAIN
ON,ON,ON,OFF,OFF,ON,ON,ON,ON,OFF,OFF,ON,ON,ON,ON,OFF,OFF
,ON,ON,ON