2.14 Spurious Emission Measurement Function
2-797
2
SCPI Device Message Details
:FETCh:SPURious[n]?
Spurious Emission Fetch
Function
This command outputs the measurement result for the Spurious
Emission measurement.
Query
:FETCh:SPURious[n]?
Response
When Result Mode is A:
(When Spurious Emission Result Type is Worst)
<judge>,<spur_1>,<range_1>,<freq_1>,<peak_1>,<margin_1>,
<limit_1>,<judge_1>,<spur_2>,<range>,<freq_2>,<peak_2>,<
margin_2>,<limit_2>,<judge_2>
・・・・・
<spur_20>,<range_20>,<freq_20>,<peak_20>,<margin_20>,<li
mit_20>,<judge_20>
(n=1 or when omitted)
(When Spurious Emission Result Type is Peaks)
<judge>,<spur_1>,<range_1>,<freq_1>,<peak_1>,<margin_1>,
<limit_1>,<judge_1>,<spur_2>,<range_2>,<freq_2>,<peak_2>
,<margin_2>,<limit_2>,<judge_2>
・・・・・
<spur_n>,<freq_n>,<peak_n>,<margin_n>,<limit_n>,<judge_n
>
(n=1 or when omitted)
When Result Mode is B:
<spur_1>,<range_1>,<freq_1>,<peak_1>,<limit_1>,<judge_1>
,<spur_2>,<range_2>,<freq_2>,<peak_2>,<limit_2>,<judge_2
>
・・・・・
<spur_n>,<range_n>,<freq_n>,<peak_n>,<limit_n>,<judge_n>
(n=1 or when omitted.)
<tracedata_1>,<tracedata_2>
・・・・
<tracedata_m>
(n=2 to 21)