EasyManua.ls Logo

Anritsu MS2840A - SPUR:PEAK:RES;SPUR:PEAK:RES?

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
Native Device Message Details
4-288
Example of Use
To stop the measurement when a “Fail” segment has been found.
SPUR:FST ON
SPUR:FST?
> 1
SPUR:PEAK:RES/SPUR:PEAK:RES?
Spurious Emission Search Resolution
Function
This command sets the spurious search resolution when Result Type is
set to Peaks.
Command
SPUR:PEAK:RES
rel_ampl_1,rel_ampl_2,rel_ampl_3,rel_ampl_4,rel_ampl_5,r
el_ampl_6,rel_ampl_7,rel_ampl_8,rel_ampl_9,rel_ampl_10,r
el_ampl_11,rel_ampl_12,rel_ampl_13,rel_ampl_14,rel_ampl_
15,rel_ampl_16,rel_ampl_17,rel_ampl_18,rel_ampl_19,rel_a
mpl_20
Query
SPUR:PEAK:RES?
Response
rel_ampl_1,rel_ampl_2,rel_ampl_3,rel_ampl_4,rel_ampl_5,r
el_ampl_6,rel_ampl_7,rel_ampl_8,rel_ampl_9,rel_ampl_10,r
el_ampl_11,rel_ampl_12,rel_ampl_13,rel_ampl_14,rel_ampl_
15,rel_ampl_16,rel_ampl_17,rel_ampl_18,rel_ampl_19,rel_a
mpl_20
Value is returned in dB units, without suffix code.
Parameter
rel_ampl_n
Spurious search resolution of Segment n
Range 0.001 to 50.00 dB
Resolution 0.001 dB
Suffix code DB
Example of Use
To set the spurious search resolution.
SPUR:PEAK:RES 6,6,6,6,6,10,10,10,6,6,6,6,6,6,6,6,6,6,6,6
SPUR:PEAK:RES?
>
6.000,6.000,6.000,6.000,6.000,10.000,10.000,10.000,6.000
,6.000,6.000,6.000,6.000,6.000,6.000,6.000,6.000,6.000,6
.000,6.000