SCPI Device Message Details
[:SENSe]:ACPower:ADVanced:OFFSet:LIST:STATe
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0
Adjacent Channel Power Offset
Function
This command sets the offset channel for Adjacent Channel Power
measurement On/Off.
Command
[:SENSe]:ACPower:ADVanced:OFFSet:LIST:STATe
<switch_1>,<switch_2>,<switch_3>,<switch_4>,<switch_5>,<
switch_6>,<switch_7>,<switch_8>
Parameter
<switch_n>
Measurement Channel n On/Off
ON|1
Measures offset channel n
OFF|0
Does not measure offset channel n
Default
switch_1
On
switch_2
On
switch_3
Off
switch_4
Off
switch_5
Off
switch_6
Off
switch_7
Off
switch_8
Off
Details
This function can be set when the following trace is active.
•
Spectrum
To query the measurement results after executing this command, use the
*WAI command to control synchronization.
Example of Use
To set the offset channel and query the results.
ACP:ADV:OFFS:LIST:STAT ON,ON,ON,ON,ON,ON,ON,ON
*WAI
FETC:ACP?