EasyManua.ls Logo

Anritsu MS2840A - [:SENSe]:CHPower:FILTer[:RRC][:STATe] ON|OFF|1|0; :CALCulate:CHPower:FILTer[:RRC][:STATe] ON|OFF|1|0

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 SCPI Device Message Details
2-488
[:SENSe]:CHPower:FILTer[:RRC][:STATe] ON|OFF|1|0
Channel Power Filter Type
Function
This command sets filter type for Channel Power measurement.
Command
[:SENSe]:CHPower:FILTer[:RRC][:STATe] <filter>
Parameter
<filter>
Filter type
0|OFF
Rectangle filter
1|ON
Root Nyquist filter (Default)
Example of Use
To set filter type to Root Nyquist.
CHP:FILT 1
Related command
This command has the same function as the following commands.
[:SENSe]:CHPower:FILTer:TYPE
:CALCulate:CHPower:FILTer[:RRC][:STATe]
:CALCulate:CHPower:FILTer[:RRC][:STATe] ON|OFF|1|0
Channel Power Filter Type
Function
This command sets filter type for Channel Power measurement.
Refer to
[:SENSe]:CHPower:FILTer[:RRC][:STATe].
Related command
This command has the same function as the following commands.
[:SENSe]:CHPower:FILTer:TYPE
[:SENSe]:CHPower:FILTer[:RRC][:STATe]

Table of Contents

Other manuals for Anritsu MS2840A

Related product manuals