2.14 Spurious Emission Measurement Function
2-787
2
SCPI Device Message Details
[:SENSe]:SPURious:TDOMain[:RANGe][:LIST]:BANDwidth:VIDeo:COUPle
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,
ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0,ON|OFF|1|0
Spurious Emission Couple Segment VBW
Function
This command sets whether the same as the value set in Segment Setup
is automatically set to VBW Value in Time Domain Setup.
Command
[:SENSe]:SPURious:TDOMain[:RANGe][:LIST]:BANDwidth:VIDeo
:COUPle <switch_n>
Parameter
<switch_n>
Shared setting On/Off
ON|1
On
OFF|0
Off
Default On
Example of Use
To set whether the same as the value set in Segment Setup is
automatically set to VBW Value in Time Domain Setup.
SPUR:TDOM:BAND:VID:COUP
ON,ON,ON,ON,OFF,OFF,ON,ON,ON,ON,ON,ON,ON,ON,OFF,OFF,ON,O
N,ON,ON