EasyManua.ls Logo

Anritsu MS2840A - SPUR:FST;SPUR:FST?

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
Native Device Message Details
4-287
4
Native Device Message Details
Example of Use
To set the stop frequency of each segment.
SPUR:FREQ:STOP
150kHz,40MHz,1.1GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz,12.5
GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz,12.5
GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz,12.5GHz
SPUR:FREQ:STOP?
>
150000,40000000,1100000000,12500000000,12500000000,12500
000000,12500000000,12500000000,12500000000,12500000000,1
2500000000,12500000000,12500000000,12500000000,125000000
00,12500000000,12500000000,12500000000,12500000000,12500
000000
SPUR:FST/SPUR:FST?
Fail Stop
Function
This command sets whether to stop the measurement when a “Fail”
segment has been found.
Command
SPUR:FST switch_com
Query
SPUR:FST?
Response
switch_res
Parameter
switch_com
Fail Stop On/Off
ON|1
Fail Stop is set to On.
OFF|0
Fail Stop is set to Off.
switch_res
Fail Stop On/Off
1
Fail Stop is set to On.
0
Fail Stop is set to Off.

Table of Contents