Anritsu MS2840A - DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV;DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV?

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
Native Device Message Details
4-81
4
Native Device Message Details
DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV/DISP:SPUR:VIEW:WIND:TRAC:Y:R
LEV?
Spurious Emission Reference Level
Function
This command sets the reference level of each segment.
Command
DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV
real_1,real_2,real_3,real_4,real_5,real_6,real_7,real_8,
real_9,real_10,real_11,real_12,real_13,real_14,real_15,r
eal_16,real_17,real_18,real_19,real_20
Query
DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV?
Response
real_1,real_2,real_3,real_4,real_5,real_6,real_7,real_8,
real_9,real_10,real_11,real_12,real_13,real_14,real_15,r
eal_16,real_17,real_18,real_19,real_20
Value is returned in dBm units, without suffix code.
Parameter
real_n
Reference level of Segment n
Range Value equivalent to120 to +50 dBm
Resolution 0.01 dB
Suffix code DBM,DM
dBm is used when omitted.
Default 0 dBm
Example of Use
To set the reference level of each segment.
DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV
0DBM,0,0,3,0,0,0,8,0,0,0,0,0,0,0,0,0,0,0,0
DISP:SPUR:VIEW:WIND:TRAC:Y:RLEV?
>
0.00,0.00,0.00,3.00,0.00,00.0,0.00,8.00,0.00,0.00,0.00,0
.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00