2.2 Level
2-75
2
SCPI Device Message Details
:DISPlay:WINDow[1]:TRACe:Y[:SCALe]:LINE[:LOGarithmic] <lines>
Log Scale Line
Function
This command sets the number of Y-axis segments in Log scale mode.
Command
:DISPlay:WINDow[1]:TRACe:Y[:SCALe]:LINE[:LOGarithmic]
<lines>
Parameter
<lines>
Number of Y-axis scale segments
10
10 segments (Default value)
12
12 segments
Details
This function can be set only in Log scale mode.
Example of Use
To set the number of Y-axis segments in Log scale mode to 12.
DISP:WIND:TRAC:Y:LINE 12
:DISPlay:WINDow[1]:TRACe:Y[:SCALe]:LINE[:LOGarithmic]?
Log Scale Line Query
Function
This command queries the number of Y-axis scale segments in Log scale
mode.
Query
:DISPlay:WINDow[1]:TRACe:Y[:SCALe]:LINE[:LOGarithmic]?
Response
<lines>
Parameter
<lines>
Number of Y-axis scale segments
10
10 segments
12
12 segments
Example of Use
To query the number of Y-axis scale segments for Log scale.
DISP:WIND:TRAC:Y:LINE?
> 12