EasyManua.ls Logo

Anritsu MS2840A - [:SENSe]:SEMask:OFFSet[1]:LIST:RLEVel <ampl_1>[,<ampl_2>[,<ampl_3>[,<ampl_4>[,<ampl_5>[,<ampl_6>[,<ampl_7>[,<ampl_8>[,<ampl_9>[,<ampl_10>[,<ampl_11>[,<ampl_12>]]]]]]]]]]]

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.13 Spectrum Emission Mask
2-653
2
SCPI Device Message Details
[:SENSe]:SEMask:OFFSet[1]:LIST:RLEVel
<ampl_1>[,<ampl_2>[,<ampl_3>[,<ampl_4>[,<ampl_5>[,<ampl_6>[,<ampl_7
>[,<ampl_8>[,<ampl_9>[,<ampl_10>[,<ampl_11>[,<ampl_12>]]]]]]]]]]]
Spectrum Emission Mask Offset Reference Level
Function
This command sets the reference level of the offset for Spectrum
Emission Mask measurement.
Command
[:SENSe]:SEMask:OFFSet[1]:LIST:RLEVel <ampl_n>
Parameter
<ampl_n>
Reference level of Offset-n
Range Value equivalent to
120 to +50 dBm
Resolution 0.01 dB
Suffix code DBM,DM
dBm is used when omitted.
Example of Use
To set the reference level of the offset to 0 dBm.
SEM:OFFS:LIST:RLEV 0,0,0,0,0,0,0,0,0,0,0,0

Table of Contents

Other manuals for Anritsu MS2840A

Related product manuals