Chapter
4
Native Device Message Details
4-348
TRIG:FRAM:SYNC/TRIG:FRAM:SYNC?
Frame Sync Source
Function
This command selects the synchronized signal source for frame trigger
start.
Command
TRIG:FRAM:SYNC sync
Query
TRIG:FRAM:SYNC?
Parameter
sync
Synchronized signal source
EXT
External input (Default)
IMM
Free run
WIF
Wideband IF detection (Wide IF Video)
Details
This command is not available for MS269x Series.
This setting is shared by the trigger signal and gate signal. The same
value is also used when frame trigger is selected as the gate signal source
for gate sweep.
Example of Use
To set the frame trigger synchronized source to Wide IF Video trigger.
TRIG:FRAM:SYNC WIF
To query the frame trigger synchronized signal source.
TRIG:FRAM:SYNC?
> WIF