Chapter 2 SCPI Device Message Detail
2-800
:READ:SPURious[n]?
Spurious Emission Read
Function
This command performs the Spurious Emission measurement and
outputs the result.
It works in the same way as the two commands are transmitted in the
following order:
:INITiate:SPURious
:FETCh:SPURious[n]?
:MEASure:SPURious[n]?
Spurious Emission Measure
Function
This command performs the Spurious Emission measurement and
outputs the result.
It works in the same way as the three commands are transmitted in the
following order:
:CONFigure:SPURious
:INITiate:SPURious
:FETCh:SPURious[n]?
:DISPlay:SPURious:ANNotation:TITLe:DATA <string>
Spurious Emission Title Entry
Function
This command registers the title character string.
Refer to
:DISPlay:ANNotation:TITLe:DATA.
Related Command
This command has the same function as the following commands.
:DISPlay:ANNotation:TITLe:DATA
:DISPlay:ACPower:ANNotation:TITLe:DATA
:DISPlay:CHPower:ANNotation:TITLe:DATA
:DISPlay:OBWidth:ANNotation:TITLe:DATA
:DISPlay:SEMask:ANNotation:TITLe:DATA
:DISPlay:BPOWer|:TXPower:ANNotation:TITLe:DATA