EasyManua.ls Logo

Anritsu MS2840A - :CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:POWer

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 SCPI Device Message Details
2-166
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:POWer
Power Peak Search
Function
This command moves the active marker to the position where the peak
power of the zone width of the active marker becomes maximum in the
measurement band.
Command
:CALCulate:MARKer[n]:MAXimum:POWer
Parameter
<n>
Marker Number
1
Specifies marker 1
2
Specifies marker 2
3
Specifies marker 3
4
Specifies marker 4
5
Specifies marker 5
6
Specifies marker 6
7
Specifies marker 7
8
Specifies marker 8
9
Specifies marker 9
10
Specifies marker 10
When omitted: Specifies marker 1
Details
This cannot be executed under the following conditions:
In Time Domain
When Scale Mode is Linear
When active trace is Blank
When Spurious Emission measurement is On and Displayed Segment
Mode is Auto
When Spectrum Emission Mask measurement is On
Example of Use
To move marker 1 to position where peak power of zone width is
maximum value.
CALC:MARK:MAX:POW