2.13 Spectrum Emission Mask
2-631
2
SCPI Device Message Details
[:SENSe]:SEMask:DETector[:FUNCtion]?
Spectrum Emission Mask Detection Mode Query
Function
This command queries the detection mode of the waveform pattern when
measuring the reference power for Spectrum Emission Mask
measurement.
Query
[:SENSe]:SEMask:DETector?
Response
<mode>
Parameter
<mode>
Detection mode selection
NORM
Simultaneous positive and negative peak
detection
POS
Positive peak detection
NEG
Negative peak detection
SAMP
Sample detection
RMS|AVER
RMS detection
Example of Use
To query the detection mode when measuring the reference power.
SEM:DET?
> POS
Related command
This command has the same function as the following command.
:CALCulate:SEMask:DETector[:FUNCtion]?