Chapter 2 SCPI Device Message Details
2-586
:CALCulate:SEMask:TYPE TPRef|PKRef|FIX
Spectrum Emission Mask Reference Type
Function
This command sets the reference for Spectrum Emission Mask
measurement.
Command
:CALCulate:SEMask:TYPE <type>
Parameter
<type>
Type of reference
TPRef
Uses the reference power as the integral power
in Channel BW.
PKRef
Uses the reference power as the peak power in
Channe l BW.
FIX
Uses the reference power as the fixed value.
Example of Use
To set the reference power to the integral power in Channel BW.
CALC:SEM:TYPE TPR
Related command
This command has the same function as the following command.
[:SENSe]:SEMask:TYPE TPRef|PKRef|FIX