Chapter 2 SCPI Device Message Details
2-196
:CALCulate:LLINe[1]|2|3|4|5|6:DATA?
Limit Edit Query
Function
This command queries the parameter settings for Limit Points on the
specified Limit Line.
Query
:CALCulate:LLINe[1]|2|3|4|5|6:DATA?
Response
<x-axis_1>,<ampl_1>,<connected_1>,<x-axis_2>,<ampl_2>,<c
onnected_2>,,,,<x-axis_n>,<ampl_n>,<connected_n>
Parameter
<x-
axis
>
Frequency Offset
Range 0 to 325 GHz (Fixed/Absolute)
100 GHz to 100 GHz (Relative)
<ampl>
Amplitude
Range 300 to 300 dBm (Fixed/Absolute)
300 to 300 dB (Relative)
<connected>
Connected to Previous point
0
Disables (No Connected)
1
Enables (Connected)
Example of Use
To query the setting for Limit Point1 on Limit Line1.
CALC:LLIN:DATA?
> 1000000000,-20.00,0,20000000000,-30,1