EasyManua.ls Logo

Anritsu MS2840A - [:SENSe]:SWEep:EGATe:HOLDoff:STATe?

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 SCPI Device Message Details
2-318
Parameter
<switch>
Gate Hold On/Off
ON|1
Gate Hold is On
OFF|0
Gate Hold is Off
Details
This command is not available for MS269x Series.
The Gate Sweep (On/Off) function is automatically set to On when this
function is set to On.
Example of Use
To set the gate input disable time setting to On.
SWE:EGAT:HOLD:STAT ON
[:SENSe]:SWEep:EGATe:HOLDoff:STATe?
Gate Hold On/Off Query
Function
This command queries the on/off status of the function to disable trigger
input for a set time, from the first trigger input until the next trigger
input, during gate sweep.
Query
[:SENSe]:SWEep:EGATe:HOLDoff:STATe?
Response
<switch>
Parameter
<switch>
Gate Hold On/Off
1
Gate Hold is On
0
Gate Hold is Off
Details
This command is not available for MS269x Series.
Example of Use
To query the gate input disable time setting.
SWE:EGAT:HOLD:STAT?
> 1