EasyManua.ls Logo

Anritsu MS2840A - [:SENSe]:CHPower[:STATe] ON|OFF|1|0; :CALCulate:CHPower[:STATe] ON|OFF|1|0

Anritsu MS2840A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 SCPI Device Message Details
2-480
[:SENSe]:CHPower[:STATe] ON|OFF|1|0
Measure Channel Power
Function
This command executes Channel Power measurement.
Command
[:SENSe]:CHPower[:STATe] <switch>
Parameter
<switch>
CHP measurement On/Off
ON|1
Sets CHP measurement to On.
OFF|0
Sets CHP measurement to Off (Default).
Example of Use
To set CHP measurement to On.
CHP ON
Related command
This command has the same function as the following command.
:CALCulate:CHPower[:STATe]
:CALCulate:CHPower[:STATe] ON|OFF|1|0
Measure Channel Power
Function
This command executes Channel Power measurement.
Refer to
[:SENSe]:CHPower[:STATe].
Related command
This command has the same function as the following command.
[:SENSe]:CHPower[:STATe]