Chapter 2 SCPI Device Message Detail
2-722
[:SENSe]:SPURious:TYPE?
Spurious Emission Result Type Query
Function
This command queries the measurement result type.
Query
[:SENSe]:SPURious:TYPE?
Response
<type>
Parameter
<type>
Measurement result type
WORS
Point with the least margin from the limit line is
displayed.
PEAK
Spurious detected by the detection resolution
and the threshold set in each segment is
displayed.
Example of Use
To query the measurement result type.
SPUR:TYPE?
> EXAM
:DISPlay:SPURious:SEGMent:MODE ON|OFF|1|0
Displayed Segment Mode
Function
This command switches the display mode of a segment.
Command
:DISPlay:SPURious:SEGMent:MODE <switch>
Parameter
<switch>
Display mode
ON|1
Auto
OFF|0
Manual
Example of Use
To set the display mode of a segment to Auto.
DISP:SPUR:SEGM:MODE ON